ANHÄNGE
Aus Display Documentation in German
(→Umrechungsfaktoren für die Stromerzeugung (spezifische Energiequellen)) |
(→Klassifikationsschema Display® für die CO2-Kennzahl) |
||
(Der Versionsvergleich bezieht 19 dazwischenliegende Versionen mit ein.) | |||
Zeile 8: | Zeile 8: | ||
- | ===<u>'''Klassifikationsschema für die Primärenergiekennzahl'''</u>=== | + | ===<u>'''Klassifikationsschema Display® für die Primärenergiekennzahl'''</u>=== |
{| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | ||
|- | |- | ||
Zeile 23: | Zeile 23: | ||
| bgcolor="00a54f"|'''A''' | | bgcolor="00a54f"|'''A''' | ||
| X ≤ 75 | | X ≤ 75 | ||
- | | X ≤ | + | | X ≤ 50 |
| X ≤ 75 | | X ≤ 75 | ||
| X ≤ 75 | | X ≤ 75 | ||
Zeile 32: | Zeile 32: | ||
|- | |- | ||
| bgcolor="4cb848"|'''B''' | | bgcolor="4cb848"|'''B''' | ||
- | |||
| 75 < X ≤ 140 | | 75 < X ≤ 140 | ||
- | | | + | | 50 < X ≤ 100 |
+ | | 125 < X ≤ 175 | ||
| 75 < X ≤ 140 | | 75 < X ≤ 140 | ||
| 500 < X ≤ 2000 | | 500 < X ≤ 2000 | ||
Zeile 42: | Zeile 42: | ||
|- | |- | ||
| bgcolor="bed630"|'''C''' | | bgcolor="bed630"|'''C''' | ||
- | | | + | | 140 < X ≤ 205 |
- | | | + | | 100 < X ≤ 150 |
- | | | + | | 125 < X ≤ 175 |
| 140 < X ≤ 205 | | 140 < X ≤ 205 | ||
| 2000 < X ≤ 3500 | | 2000 < X ≤ 3500 | ||
Zeile 52: | Zeile 52: | ||
|- | |- | ||
| bgcolor="fff101"|'''D''' | | bgcolor="fff101"|'''D''' | ||
- | |||
| 205 < X ≤ 270 | | 205 < X ≤ 270 | ||
- | | | + | | 150 < X ≤ 200 |
+ | | 175 < X ≤ 225 | ||
| 205 < X ≤ 270 | | 205 < X ≤ 270 | ||
| 3500 < X ≤ 5000 | | 3500 < X ≤ 5000 | ||
Zeile 62: | Zeile 62: | ||
|- | |- | ||
| bgcolor="fcb814"|'''E''' | | bgcolor="fcb814"|'''E''' | ||
- | |||
| 270 < X ≤ 335 | | 270 < X ≤ 335 | ||
- | | | + | | 200 < X ≤ 250 |
+ | | 225 < X ≤ 275 | ||
| 270 < X ≤ 335 | | 270 < X ≤ 335 | ||
| 5000 < X ≤ 6500 | | 5000 < X ≤ 6500 | ||
Zeile 72: | Zeile 72: | ||
|- | |- | ||
| bgcolor="f36e21"|'''F''' | | bgcolor="f36e21"|'''F''' | ||
- | |||
| 335 < X ≤ 400 | | 335 < X ≤ 400 | ||
- | | | + | | 250 < X ≤ 300 |
+ | | 275 < X ≤ 325 | ||
| 335 < X ≤ 400 | | 335 < X ≤ 400 | ||
| 6500 < X ≤ 8000 | | 6500 < X ≤ 8000 | ||
Zeile 82: | Zeile 82: | ||
|- | |- | ||
| bgcolor="ee1d23"|'''G''' | | bgcolor="ee1d23"|'''G''' | ||
- | |||
| X > 400 | | X > 400 | ||
- | | X > | + | | X > 300 |
+ | | X > 325 | ||
| X > 400 | | X > 400 | ||
| X > 8000 | | X > 8000 | ||
Zeile 109: | Zeile 109: | ||
| X ≤ 100 | | X ≤ 100 | ||
| X ≤ 50 | | X ≤ 50 | ||
- | | X ≤ | + | | X ≤ 50 |
| X ≤ 75 | | X ≤ 75 | ||
| X ≤ 125 | | X ≤ 125 | ||
Zeile 119: | Zeile 119: | ||
| 100 < X ≤ 200 | | 100 < X ≤ 200 | ||
| 50 < X ≤ 100 | | 50 < X ≤ 100 | ||
- | | | + | | 50 < X ≤ 110 |
| 75 < X ≤ 145 | | 75 < X ≤ 145 | ||
| 125 < X ≤ 245 | | 125 < X ≤ 245 | ||
Zeile 129: | Zeile 129: | ||
| 200 < X ≤ 300 | | 200 < X ≤ 300 | ||
| 100 < X ≤ 150 | | 100 < X ≤ 150 | ||
- | | | + | | 110 < X ≤ 170 |
| 145 < X ≤ 215 | | 145 < X ≤ 215 | ||
| 245 < X ≤ 365 | | 245 < X ≤ 365 | ||
Zeile 139: | Zeile 139: | ||
| 300 < X ≤ 400 | | 300 < X ≤ 400 | ||
| 150 < X ≤ 200 | | 150 < X ≤ 200 | ||
- | | | + | | 170 < X ≤ 230 |
| 215 < X ≤ 285 | | 215 < X ≤ 285 | ||
| 365 < X ≤ 485 | | 365 < X ≤ 485 | ||
Zeile 149: | Zeile 149: | ||
| 400 < X ≤ 500 | | 400 < X ≤ 500 | ||
| 200 < X ≤ 250 | | 200 < X ≤ 250 | ||
- | | | + | | 230 < X ≤ 290 |
| 285 < X ≤ 355 | | 285 < X ≤ 355 | ||
| 485 < X ≤ 605 | | 485 < X ≤ 605 | ||
Zeile 159: | Zeile 159: | ||
| 500 < X ≤ 600 | | 500 < X ≤ 600 | ||
| 250 < X ≤ 300 | | 250 < X ≤ 300 | ||
- | | | + | | 290 < X ≤ 350 |
| 335 < X ≤ 425 | | 335 < X ≤ 425 | ||
| 605 < X ≤ 725 | | 605 < X ≤ 725 | ||
Zeile 169: | Zeile 169: | ||
| X > 600 | | X > 600 | ||
| X > 300 | | X > 300 | ||
- | | X > | + | | X > 350 |
| X > 425 | | X > 425 | ||
| X > 725 | | X > 725 | ||
Zeile 177: | Zeile 177: | ||
- | ===<u>'''Klassifikationsschema für die CO2-Kennzahl'''</u>=== | + | '''Klassifikationsschema für die Primärenergiekennzahl nach GEAK (Schweiz)''' <br/> |
+ | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | ||
+ | |- | ||
+ | ! bgcolor="999A9A"|Klassifikation GEAK | ||
+ | kWh/(m².an) | ||
+ | ! bgcolor="cccccc"|Mehrfamilienhaus (I) | ||
+ | ! bgcolor="cccccc"|Ein-/Zweifamilienhaus (II) | ||
+ | ! bgcolor="cccccc"|Verwaltung (III) | ||
+ | ! bgcolor="cccccc"|Schule(IV) | ||
+ | ! bgcolor="cccccc"|Verkaufsstätte (IV) | ||
+ | ! bgcolor="cccccc"|Restaurant (VI) | ||
+ | |||
+ | |- | ||
+ | | bgcolor="999A9A"|'''entsprechender Gebäudetyp Display®''' <br/> | ||
+ | | bgcolor="cccccc"|'''Mehrfamilienhaus (11)''' | ||
+ | | bgcolor="cccccc"|'''Ein-/Zweifamilienhaus (12)''' | ||
+ | | bgcolor="cccccc"|'''Verwaltung (4)''' | ||
+ | | bgcolor="cccccc"|'''Kindergarten (1)''' <br/> | ||
+ | '''Allgemeinbildende Schule (2)''' <br/> | ||
+ | '''Enseignement professionnel (3)''' | ||
+ | | bgcolor="cccccc"|'''Verkaufsstätte (13)''' | ||
+ | | bgcolor="cccccc"|'''Restaurant (14)''' | ||
+ | |- | ||
+ | | bgcolor="00a54f"|'''A''' | ||
+ | | X ≤ 59 | ||
+ | | X ≤ 56 | ||
+ | | X ≤ 46 | ||
+ | | X ≤ 36 | ||
+ | | X ≤ 53 | ||
+ | | X ≤ 96 | ||
+ | |- | ||
+ | | bgcolor="4cb848"|'''B''' | ||
+ | | 59 < X ≤ 118 | ||
+ | | 56 < X ≤ 113 | ||
+ | | 46 < X ≤ 92 | ||
+ | | 36 < X ≤ 71 | ||
+ | | 53 < X ≤ 105 | ||
+ | | 96 < X ≤ 191 | ||
+ | |- | ||
+ | | bgcolor="bed630"|'''C''' | ||
+ | | 118 < X ≤ 177 | ||
+ | | 113 < X ≤ 169 | ||
+ | | 92 < X ≤ 138 | ||
+ | | 71 < X ≤ 107 | ||
+ | | 105 < X ≤ 158 | ||
+ | | 191 < X ≤ 287 | ||
+ | |- | ||
+ | | bgcolor="fff101"|'''D''' | ||
+ | | 177 < X ≤ 237 | ||
+ | | 169 < X ≤ 226 | ||
+ | | 138 < X ≤ 184 | ||
+ | | 107 < X ≤ 142 | ||
+ | | 158 < X ≤ 210 | ||
+ | | 287 < X ≤ 382 | ||
+ | |- | ||
+ | | bgcolor="fcb814"|'''E''' | ||
+ | | 237 < X ≤ 296 | ||
+ | | 226 < X ≤ 282 | ||
+ | | 184 < X ≤ 231 | ||
+ | | 142 < X ≤ 178 | ||
+ | | 210 < X ≤ 263 | ||
+ | | 382 < X ≤ 478 | ||
+ | |- | ||
+ | | bgcolor="f36e21"|'''F''' | ||
+ | | 296 < X ≤ 355 | ||
+ | | 282 < X ≤ 338 | ||
+ | | 231 < X ≤ 277 | ||
+ | | 178 < X ≤ 213 | ||
+ | | 263 < X ≤ 315 | ||
+ | | 478 < X ≤ 573 | ||
+ | |- | ||
+ | | bgcolor="ee1d23"|'''G''' | ||
+ | | X > 355 | ||
+ | | X > 338 | ||
+ | | X > 277 | ||
+ | | X > 213 | ||
+ | | X > 315 | ||
+ | | X > 573 | ||
+ | |} | ||
+ | <br/> | ||
+ | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | ||
+ | |- | ||
+ | ! bgcolor="999A9A"|Klassifikation GEAK | ||
+ | kWh/(m².an) | ||
+ | ! bgcolor="cccccc"|Soziales/Kulturelles Gebäude (VII) | ||
+ | ! bgcolor="cccccc"|Krankenhaus (VIII) | ||
+ | ! bgcolor="cccccc"|Industrie (IX) | ||
+ | ! bgcolor="cccccc"|Dépôt/Betriebshof (X) | ||
+ | ! bgcolor="cccccc"|Sporthalle (XI) | ||
+ | ! bgcolor="cccccc"|Hallenbad (XII) | ||
+ | |||
+ | |- | ||
+ | | bgcolor="999A9A"|'''entsprechender Gebäudetyp Display®''' <br/> | ||
+ | | bgcolor="cccccc"|'''Soziales/Kulturelles Gebäude (8)''' | ||
+ | | bgcolor="cccccc"|'''Krankenhaus(9)''' | ||
+ | | bgcolor="cccccc"|'''Industrie (15)''' <br/> | ||
+ | '''Gesundheitswesen (10)''' | ||
+ | | bgcolor="cccccc"|'''Dépôt/Betriebshof (7)''' | ||
+ | | bgcolor="cccccc"|'''Sporthalle (6)''' | ||
+ | | bgcolor="cccccc"|'''Hallenbad (5)''' | ||
+ | |- | ||
+ | | bgcolor="00a54f"|'''A''' | ||
+ | | X ≤ 50 | ||
+ | | X ≤ 64 | ||
+ | | X ≤ 38 | ||
+ | | X ≤ 22 | ||
+ | | X ≤ 76 | ||
+ | | X ≤ 130 | ||
+ | |- | ||
+ | | bgcolor="4cb848"|'''B''' | ||
+ | | 50 < X ≤ 99 | ||
+ | | 64 < X ≤ 128 | ||
+ | | 38 < X ≤ 76 | ||
+ | | 22 < X ≤ 43 | ||
+ | | 76 < X ≤ 151 | ||
+ | | 130 < X ≤ 259 | ||
+ | |- | ||
+ | | bgcolor="bed630"|'''C''' | ||
+ | | 99 < X ≤ 149 | ||
+ | | 128 < X ≤ 192 | ||
+ | | 76 < X ≤ 114 | ||
+ | | 43 < X ≤ 65 | ||
+ | | 151 < X ≤ 227 | ||
+ | | 259 < X ≤ 389 | ||
+ | |- | ||
+ | | bgcolor="fff101"|'''D''' | ||
+ | | 149 < X ≤ 198 | ||
+ | | 192 < X ≤ 256 | ||
+ | | 114 < X ≤ 152 | ||
+ | | 65 < X ≤ 86 | ||
+ | | 227 < X ≤ 302 | ||
+ | | 389 < X ≤ 518 | ||
+ | |- | ||
+ | | bgcolor="fcb814"|'''E''' | ||
+ | | 198 < X ≤ 248 | ||
+ | | 256 < X ≤ 320 | ||
+ | | 152 < X ≤ 190 | ||
+ | | 86 < X ≤ 108 | ||
+ | | 302 < X ≤ 378 | ||
+ | | 518 < X ≤ 648 | ||
+ | |- | ||
+ | | bgcolor="f36e21"|'''F''' | ||
+ | | 248 < X ≤ 297 | ||
+ | | 320 < X ≤ 384 | ||
+ | | 190 < X ≤ 228 | ||
+ | | 108 < X ≤ 129 | ||
+ | | 378 < X ≤ 453 | ||
+ | | 648 < X ≤ 777 | ||
+ | |- | ||
+ | | bgcolor="ee1d23"|'''G''' | ||
+ | | X > 297 | ||
+ | | X > 384 | ||
+ | | X > 228 | ||
+ | | X > 129 | ||
+ | | X > 453 | ||
+ | | X > 777 | ||
+ | |} | ||
+ | <br/> | ||
+ | |||
+ | ===<u>'''Klassifikationsschema Display® für die CO2-Kennzahl'''</u>=== | ||
{| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | ||
|- | |- | ||
Zeile 192: | Zeile 351: | ||
| bgcolor="00a54f"|'''A''' | | bgcolor="00a54f"|'''A''' | ||
| X ≤ 15 | | X ≤ 15 | ||
- | | X ≤ | + | | X ≤ 10 |
| X ≤ 15 | | X ≤ 15 | ||
| X ≤ 15 | | X ≤ 15 | ||
Zeile 201: | Zeile 360: | ||
|- | |- | ||
| bgcolor="4cb848"|'''B''' | | bgcolor="4cb848"|'''B''' | ||
- | |||
| 15 < X ≤ 28 | | 15 < X ≤ 28 | ||
- | | 15 < X ≤ | + | | 10 < X ≤ 20 |
+ | | 15 < X ≤ 25 | ||
| 15 < X ≤ 28 | | 15 < X ≤ 28 | ||
| 100 < X ≤ 400 | | 100 < X ≤ 400 | ||
Zeile 211: | Zeile 370: | ||
|- | |- | ||
| bgcolor="bed630"|'''C''' | | bgcolor="bed630"|'''C''' | ||
- | | | + | | 28 < X ≤ 41 |
- | | | + | | 20 < X ≤ 30 |
- | | | + | | 25 < X ≤ 35 |
| 28 < X ≤ 41 | | 28 < X ≤ 41 | ||
| 400 < X ≤ 700 | | 400 < X ≤ 700 | ||
Zeile 221: | Zeile 380: | ||
|- | |- | ||
| bgcolor="fff101"|'''D''' | | bgcolor="fff101"|'''D''' | ||
- | | | + | | 41 < X ≤ 54 |
- | | | + | | 30 < X ≤ 40 |
- | | | + | | 35 < X ≤ 45 |
| 41 < X ≤ 54 | | 41 < X ≤ 54 | ||
| 700 < X ≤ 1000 | | 700 < X ≤ 1000 | ||
Zeile 231: | Zeile 390: | ||
|- | |- | ||
| bgcolor="fcb814"|'''E''' | | bgcolor="fcb814"|'''E''' | ||
- | | | + | | 54 < X ≤ 67 |
- | | | + | | 40 < X ≤ 50 |
- | | | + | | 45 < X ≤ 55 |
| 54 < X ≤ 67 | | 54 < X ≤ 67 | ||
| 1000 < X ≤ 1300 | | 1000 < X ≤ 1300 | ||
Zeile 241: | Zeile 400: | ||
|- | |- | ||
| bgcolor="f36e21"|'''F''' | | bgcolor="f36e21"|'''F''' | ||
- | |||
| 67 < X ≤ 80 | | 67 < X ≤ 80 | ||
- | | | + | | 50 < X ≤ 60 |
+ | | 55 < X ≤ 65 | ||
| 67 < X ≤ 80 | | 67 < X ≤ 80 | ||
| 1300 < X ≤ 1600 | | 1300 < X ≤ 1600 | ||
Zeile 251: | Zeile 410: | ||
|- | |- | ||
| bgcolor="ee1d23"|'''G''' | | bgcolor="ee1d23"|'''G''' | ||
- | |||
| X > 80 | | X > 80 | ||
- | | X > | + | | X > 60 |
+ | | X > 65 | ||
| X > 80 | | X > 80 | ||
| X > 1600 | | X > 1600 | ||
Zeile 278: | Zeile 437: | ||
| X ≤ 20 | | X ≤ 20 | ||
| X ≤ 10 | | X ≤ 10 | ||
- | | X ≤ | + | | X ≤ 10 |
| X ≤ 15 | | X ≤ 15 | ||
| X ≤ 25 | | X ≤ 25 | ||
Zeile 288: | Zeile 447: | ||
| 20 < X ≤ 36 | | 20 < X ≤ 36 | ||
| 10 < X ≤ 20 | | 10 < X ≤ 20 | ||
- | | | + | | 10 < X ≤ 22 |
| 15 < X ≤ 29 | | 15 < X ≤ 29 | ||
| 25 < X ≤ 49 | | 25 < X ≤ 49 | ||
Zeile 298: | Zeile 457: | ||
| 36 < X ≤ 52 | | 36 < X ≤ 52 | ||
| 20 < X ≤ 30 | | 20 < X ≤ 30 | ||
- | | | + | | 22 < X ≤ 34 |
| 29 < X ≤ 43 | | 29 < X ≤ 43 | ||
| 49 < X ≤ 73 | | 49 < X ≤ 73 | ||
Zeile 308: | Zeile 467: | ||
| 52 < X ≤ 68 | | 52 < X ≤ 68 | ||
| 30 < X ≤ 40 | | 30 < X ≤ 40 | ||
- | | | + | | 34 < X ≤ 46 |
| 43 < X ≤ 57 | | 43 < X ≤ 57 | ||
| 73 < X ≤ 97 | | 73 < X ≤ 97 | ||
Zeile 318: | Zeile 477: | ||
| 68 < X ≤ 86 | | 68 < X ≤ 86 | ||
| 40 < X ≤ 50 | | 40 < X ≤ 50 | ||
- | | | + | | 46 < X ≤ 58 |
| 57 < X ≤ 71 | | 57 < X ≤ 71 | ||
| 97 < X ≤ 121 | | 97 < X ≤ 121 | ||
Zeile 328: | Zeile 487: | ||
| 86 < X ≤ 102 | | 86 < X ≤ 102 | ||
| 50 < X ≤ 60 | | 50 < X ≤ 60 | ||
- | | | + | | 58 < X ≤ 70 |
| 71 < X ≤ 85 | | 71 < X ≤ 85 | ||
| 121 < X ≤ 145 | | 121 < X ≤ 145 | ||
Zeile 338: | Zeile 497: | ||
| X > 102 | | X > 102 | ||
| X > 60 | | X > 60 | ||
- | | X > | + | | X > 70 |
| X > 85 | | X > 85 | ||
| X > 145 | | X > 145 | ||
Zeile 345: | Zeile 504: | ||
|} | |} | ||
+ | |||
+ | |||
+ | '''Klassifikationsschema für die CO2-Kennzahl Version GEAK(Schweiz)'''<br/> | ||
+ | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | ||
+ | |- | ||
+ | ! bgcolor="999A9A"|Klassifikation GEAK | ||
+ | kg/(m².an) | ||
+ | ! bgcolor="cccccc"|Mehrfamilienhaus (I) | ||
+ | ! bgcolor="cccccc"|Ein-/Zweifamilienhaus (II) | ||
+ | ! bgcolor="cccccc"|Verwaltung (III) | ||
+ | ! bgcolor="cccccc"|Schule(IV) | ||
+ | ! bgcolor="cccccc"|Verkaufsstätte (IV) | ||
+ | ! bgcolor="cccccc"|Restaurant (VI) | ||
+ | |||
+ | |- | ||
+ | | bgcolor="999A9A"|'''entsprechender Gebäudetyp Display®''' <br/> | ||
+ | | bgcolor="cccccc"|'''Mehrfamilienhaus (11)''' | ||
+ | | bgcolor="cccccc"|'''Ein-/Zweifamilienhaus (12)''' | ||
+ | | bgcolor="cccccc"|'''Verwaltung (4)''' | ||
+ | | bgcolor="cccccc"|'''Kindergarten (1)''' <br/> | ||
+ | '''Allgemeinbildende Schule (2)''' <br/> | ||
+ | '''Enseignement professionnel (3)''' | ||
+ | | bgcolor="cccccc"|'''Verkaufsstätte (13)''' | ||
+ | | bgcolor="cccccc"|'''Restaurant (14)''' | ||
+ | |- | ||
+ | | bgcolor="00a54f"|'''A''' | ||
+ | | X ≤ 15 | ||
+ | | X ≤ 14 | ||
+ | | X ≤ 12 | ||
+ | | X ≤ 9 | ||
+ | | X ≤ 14 | ||
+ | | X ≤ 23 | ||
+ | |- | ||
+ | | bgcolor="4cb848"|'''B''' | ||
+ | | 15 < X ≤ 29 | ||
+ | | 14 < X ≤ 27 | ||
+ | | 12 < X ≤ 23 | ||
+ | | 9 < X ≤ 17 | ||
+ | | 14 < X ≤ 27 | ||
+ | | 23 < X ≤ 46 | ||
+ | |- | ||
+ | | bgcolor="bed630"|'''C''' | ||
+ | | 29 < X ≤ 44 | ||
+ | | 27 < X ≤ 41 | ||
+ | | 23 < X ≤ 35 | ||
+ | | 9 < X ≤ 26 | ||
+ | | 14 < X ≤ 41 | ||
+ | | 23 < X ≤ 69 | ||
+ | |- | ||
+ | | bgcolor="fff101"|'''D''' | ||
+ | | 44 < X ≤ 58 | ||
+ | | 41 < X ≤ 54 | ||
+ | | 35 < X ≤ 46 | ||
+ | | 26 < X ≤ 34 | ||
+ | | 41 < X ≤ 54 | ||
+ | | 69 < X ≤ 92 | ||
+ | |- | ||
+ | | bgcolor="fcb814"|'''E''' | ||
+ | | 58 < X ≤ 73 | ||
+ | | 54 < X ≤ 68 | ||
+ | | 46 < X ≤ 58 | ||
+ | | 34 < X ≤ 43 | ||
+ | | 54 < X ≤ 68 | ||
+ | | 92 < X ≤ 115 | ||
+ | |- | ||
+ | | bgcolor="f36e21"|'''F''' | ||
+ | | 73 < X ≤ 87 | ||
+ | | 68 < X ≤ 81 | ||
+ | | 58 < X ≤ 69 | ||
+ | | 43 < X ≤ 51 | ||
+ | | 68 < X ≤ 81 | ||
+ | | 115 < X ≤ 138 | ||
+ | |- | ||
+ | | bgcolor="ee1d23"|'''G''' | ||
+ | | X > 87 | ||
+ | | X > 81 | ||
+ | | X > 69 | ||
+ | | X > 51 | ||
+ | | X > 81 | ||
+ | | X > 138 | ||
+ | |} | ||
+ | <br/> | ||
+ | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | ||
+ | |- | ||
+ | ! bgcolor="999A9A"|KlassifiKation GEAK | ||
+ | kg/(m².an) | ||
+ | ! bgcolor="cccccc"|Soziales/Kulturelles Gebäude (VII) | ||
+ | ! bgcolor="cccccc"|Krankenhaus (VIII) | ||
+ | ! bgcolor="cccccc"|Industrie (IX) | ||
+ | ! bgcolor="cccccc"|Dépôt/Betriebshof (X) | ||
+ | ! bgcolor="cccccc"|Sporthalle (XI) | ||
+ | ! bgcolor="cccccc"|Hallenbad (XII) | ||
+ | |||
+ | |- | ||
+ | | bgcolor="999A9A"|'''entsprechender Gebäudetyp Display®''' <br/> | ||
+ | | bgcolor="cccccc"|'''Soziales/Kulturelles Gebäude (8)''' | ||
+ | | bgcolor="cccccc"|'''Krankenhaus(9)''' | ||
+ | | bgcolor="cccccc"|'''Industrie (15)''' <br/> | ||
+ | '''Gesundheitswesen (10)''' | ||
+ | | bgcolor="cccccc"|'''Dépôt/Betriebshof (7)''' | ||
+ | | bgcolor="cccccc"|'''Sporthalle (6)''' | ||
+ | | bgcolor="cccccc"|'''Hallenbad (5)''' | ||
+ | |- | ||
+ | | bgcolor="00a54f"|'''A''' | ||
+ | | X ≤ 12 | ||
+ | | X ≤ 16 | ||
+ | | X ≤ 10 | ||
+ | | X ≤ 5 | ||
+ | | X ≤ 17 | ||
+ | | X ≤ 31 | ||
+ | |- | ||
+ | | bgcolor="4cb848"|'''B''' | ||
+ | | 12 < X ≤ 24 | ||
+ | | 16 < X ≤ 31 | ||
+ | | 10 < X ≤ 19 | ||
+ | | 5 < X ≤ 10 | ||
+ | | 17 < X ≤ 34 | ||
+ | | 31 < X ≤ 62 | ||
+ | |- | ||
+ | | bgcolor="bed630"|'''C''' | ||
+ | | 24 < X ≤ 36 | ||
+ | | 31 < X ≤ 47 | ||
+ | | 19 < X ≤ 29 | ||
+ | | 10 < X ≤ 15 | ||
+ | | 34 < X ≤ 51 | ||
+ | | 62 < X ≤ 93 | ||
+ | |- | ||
+ | | bgcolor="fff101"|'''D''' | ||
+ | | 36 < X ≤ 48 | ||
+ | | 47 < X ≤ 62 | ||
+ | | 29 < X ≤ 38 | ||
+ | | 15 < X ≤ 20 | ||
+ | | 51 < X ≤ 68 | ||
+ | | 93 < X ≤ 124 | ||
+ | |- | ||
+ | | bgcolor="fcb814"|'''E''' | ||
+ | | 48 < X ≤ 60 | ||
+ | | 62 < X ≤ 78 | ||
+ | | 38 < X ≤ 48 | ||
+ | | 20 < X ≤ 25 | ||
+ | | 68 < X ≤ 85 | ||
+ | | 124 < X ≤ 155 | ||
+ | |- | ||
+ | | bgcolor="f36e21"|'''F''' | ||
+ | | 60 < X ≤ 72 | ||
+ | | 78 < X ≤ 93 | ||
+ | | 48 < X ≤ 57 | ||
+ | | 25 < X ≤ 30 | ||
+ | | 85 < X ≤ 102 | ||
+ | | 155 < X ≤ 186 | ||
+ | |- | ||
+ | | bgcolor="ee1d23"|'''G''' | ||
+ | | X > 72 | ||
+ | | X > 93 | ||
+ | | X > 57 | ||
+ | | X > 30 | ||
+ | | X > 102 | ||
+ | | X > 186 | ||
+ | |} | ||
+ | <br/> | ||
===<u>'''Klassifikationsschema für die Wasserkennzahl '''</u>=== | ===<u>'''Klassifikationsschema für die Wasserkennzahl '''</u>=== | ||
Zeile 522: | Zeile 841: | ||
|} | |} | ||
<br/> | <br/> | ||
+ | <br> | ||
+ | ===<u>Klassifikationsschema für die Raumtemperatur in C°</u>=== | ||
+ | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | ||
+ | |- | ||
+ | ! bgcolor="cccccc"|kWh/(m².yr) | ||
+ | ! bgcolor="cccccc"|Building Type <br> 1/2/3/4/8/9/11/12 | ||
+ | ! bgcolor="cccccc"|Building Type <br> 6/13/15 | ||
+ | ! bgcolor="cccccc"|Building Type <br> 10/16 | ||
+ | ! bgcolor="cccccc"|Building Type <br> 5 | ||
+ | ! bgcolor="cccccc"|Building Type <br> 14 | ||
+ | |- | ||
+ | | bgcolor="00a54f"|'''A''' | ||
+ | | 19° ≤ X< 20° | ||
+ | | 17,5° ≤ X< 18,5° | ||
+ | | 21,5° ≤ X< 22,5° | ||
+ | | 27,5° ≤ X< 28,5° | ||
+ | | 20,5° ≤ X< 21,5° | ||
+ | |- | ||
+ | | bgcolor="4cb848"|'''B''' | ||
+ | | 18,5° ≤ X < 19,0° <br> or<br> 20,0° ≤ X< 21,0° | ||
+ | | 17,0° ≤ X < 17,5°<br> or<br> 18,5° ≤ X< 19,5° | ||
+ | | 21,0° ≤ X < 21,5°<br> or <br> 22,5° ≤ X< 23,5° | ||
+ | | 27,0° ≤ X < 27,5°<br> or<br> 28,5° ≤ X< 29,5° | ||
+ | | 20,0° ≤ X < 20,5°<br> or<br>21,5° ≤ X< 22,5° | ||
+ | |- | ||
+ | | bgcolor="bed630"|'''C''' | ||
+ | | 18,0° ≤ X < 18,5° <br> Or <br> 21,0° ≤ X< 22,0° | ||
+ | | 16,5° ≤ X < 17,0°<br> or <br> 19,5° ≤ X< 20,5° | ||
+ | | 20,5° ≤ X < 21,0°<br> or<br> 23,5° ≤ X< 24,5° | ||
+ | | 26,5° ≤ X < 27,0°<br> Or <br> 29,5° < X ≤ 30,5° | ||
+ | | 19,5° ≤ X < 20,0°<br> Or<br> 22,5° < X ≤ 23,5° | ||
+ | |- | ||
+ | | bgcolor="fff101"|'''D''' | ||
+ | | 17,5° ≤ X < 18,0° <br> OR <br>22,0° ≤ X< 23,0° | ||
+ | | 16,0° ≤ X < 16,5°<br> or<br> 20,5° ≤ X< 21,5° | ||
+ | | 20,0° ≤ X < 20,5°<br> or <br> 24,5° ≤ X< 25,5° | ||
+ | | 26,0° ≤ X < 27,5° <br> OR <br> 30,5° < X ≤ 31,5° | ||
+ | | 19,0° ≤ X < 19,5° <br> OR <br>23,5° < X ≤ 24,5° | ||
+ | |- | ||
+ | | bgcolor="fcb814"|'''E''' | ||
+ | | 17,0° ≤ X < 17,5° <br> OR <br> 23,0° ≤ X< 24,0° | ||
+ | | 15,5° ≤ X < 16,0°<br> or<br> 21,5° ≤ X< 22,5° | ||
+ | | 19,5° ≤ X < 20,0°<br> or<br> 25,5° ≤ X< 26,5° | ||
+ | | 25,5° ≤ X < 26,0° <br> OR <br> 31,5° < X ≤ 32,5° | ||
+ | | 18,5° ≤ X < 19,0° <br> OR <br>24,5° < X ≤ 25,5° | ||
+ | |- | ||
+ | | bgcolor="f36e21"|'''F''' | ||
+ | | 16,5° ≤ X < 17,0° <br> OR <br> 24,0° ≤ X< 25,0° | ||
+ | | 15,0° ≤ X < 15,5°<br> or<br> 22,5° ≤ X< 23,5° | ||
+ | | 19,0° ≤ X < 19,5°<br> or<br>26,5° ≤ X< 27,5° | ||
+ | | 25,0° ≤ X < 25,5° <br> OR <br> 32,5° < X ≤ 33,5° | ||
+ | | 18,0° ≤ X < 18,5°<br> OR <br> 25,5° < X ≤ 26,5° | ||
+ | |- | ||
+ | | bgcolor="ee1d23"|'''G''' | ||
+ | | 16,0° < X > 25,0° | ||
+ | | 15,0° < X > 23,5° | ||
+ | | 19,0° < X > 27,5° | ||
+ | | 25,0° < X > 33,5° | ||
+ | | 18,0° < X > 26,5° | ||
+ | |} | ||
+ | <br> | ||
+ | Gebäudetypen: | ||
+ | *1: Kindergarten | ||
+ | *2-3 : Allgemeinbildende Schule und Berufsschule | ||
+ | *4 : Verwaltungsgebäude | ||
+ | *5 : Swimmhalle | ||
+ | *6 : Sporthalle | ||
+ | *7 : Depot/Betriebshof | ||
+ | *8 : Soziokulturelles Gebäude | ||
+ | *9 : Heim | ||
+ | *10 : Gebäude der öffentlichen Sicherheit | ||
+ | *11-12: Mehrfamilienhaus oder Ein-/Zweifamilienhaus | ||
+ | *13 : Verkaufsstätte | ||
+ | *14 : Restaurant | ||
+ | *15 : Industriegebäude | ||
+ | *16 : Krankenhaus | ||
+ | <br> | ||
+ | |||
+ | ===<u>Klassifikationsschema für die Raumluftqualität </u>=== | ||
+ | |||
+ | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" | ||
+ | |- | ||
+ | ! bgcolor="cccccc"|kWh/(m².yr) | ||
+ | ! bgcolor="cccccc"|Indoor Air quality (ppm)<br> <b>All Building types </b> | ||
+ | |- | ||
+ | | bgcolor="00a54f"|'''A''' | ||
+ | | X ≤ 750 | ||
+ | |- | ||
+ | | bgcolor="4cb848"|'''B''' | ||
+ | | 750 < X ≤ 900 | ||
+ | |- | ||
+ | | bgcolor="bed630"|'''C''' | ||
+ | | 900 < X ≤ 1200 | ||
+ | |- | ||
+ | | bgcolor="fff101"|'''D''' | ||
+ | | 1200 < X ≤ 1500 | ||
+ | |- | ||
+ | | bgcolor="fcb814"|'''E''' | ||
+ | | 1500 < X ≤ 1800 | ||
+ | |- | ||
+ | | bgcolor="f36e21"|'''F''' | ||
+ | | 1800 < X ≤ 2100 | ||
+ | |- | ||
+ | | bgcolor="ee1d23"|'''G''' | ||
+ | | X > 2100 | ||
+ | |} | ||
+ | <br> | ||
<br/> | <br/> | ||
Zeile 561: | Zeile 987: | ||
<br/> | <br/> | ||
''(1) Source: Société suisse des ingénieurs et des architectes (SIA)'' | ''(1) Source: Société suisse des ingénieurs et des architectes (SIA)'' | ||
+ | |||
+ | |||
===<u>'''Umrechnungsfaktoren für den Energieträger'''</u>=== | ===<u>'''Umrechnungsfaktoren für den Energieträger'''</u>=== | ||
- | + | '''Umrechnungsfaktoren Endenergie zu Primärenergie nach der Display® bzw. GEAK Methodik''' | |
- | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: | + | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 100%" |
|- | |- | ||
- | ! bgcolor="cccccc"|Energie oder Energiequelle | + | ! bgcolor="cccccc"|Energie oder Energiequelle ''(1)'' |
- | ! bgcolor="cccccc"|Umrechnungsfaktor Endenergie zu Primärenergie [kWh/kWh] | + | ! bgcolor="cccccc" colspan="2"| Umrechnungsfaktor Endenergie zu Primärenergie [kWh/kWh] |
- | ! bgcolor="cccccc"|Art des Umrechnungsfaktors | + | ! bgcolor="cccccc" colspan="1"| Art des Umrechnungsfaktors |
- | ! bgcolor="cccccc"|Umrechnunsfaktor Endenergie zu CO2-Aquivalente[kg/kWh] | + | ! bgcolor="cccccc" colspan="2"| Umrechnunsfaktor Endenergie zu CO2-Aquivalente [kg/kWh] |
|- | |- | ||
- | | | + | | |
+ | | bgcolor="4296dd"|'''Display/SIA 2031 (2009)''' | ||
+ | | bgcolor="469e76"|'''GEAK''' | ||
+ | | bgcolor="4296dd"|'''Display''' | ||
+ | | bgcolor="4296dd"|'''Display/SIA 2031 (2009)''' | ||
+ | | bgcolor="469e76"|'''GEAK''' | ||
|- | |- | ||
- | | | + | |'''Erdgas'''||1,15||1||KEVtotal||0,2400||0.24 |
|- | |- | ||
- | | | + | |'''Flüssiggas'''||1,15||''kA''||KEVtotal||0,2400||''kA'' |
|- | |- | ||
- | | | + | |'''Heizöl'''||1,24||1||KEVtotal||0,3000||0.3 |
|- | |- | ||
- | |Steinkohle||1, | + | |'''Steinkohle'''||1,19||1||KEVtotal||0,3900||0.43 |
|- | |- | ||
- | |Braunkohle||1, | + | |'''Braunkohle'''||1,66||1||KEVtotal||0,4300||0.43 |
|- | |- | ||
- | |Holzscheite||1, | + | |'''Holzscheite'''||1,06||0.7||KEVtotal||0,0100||0.01 |
|- | |- | ||
- | |Holzhackschnitzel||1, | + | |'''Holzhackschnitzel'''||1,14||0.7||KEVtotal||0,0100||0.01 |
|- | |- | ||
- | |Holzpellets||1, | + | |'''Holzpellets'''||1,22||0.7||KEVtotal||0,0400||0.01 |
|- | |- | ||
- | | | + | |'''Solarthermie'''||1,17||''kA''||KEVtotal||0,0479||''kA'' |
+ | |- | ||
+ | |'''PV - monocrystalline'''||1.66||0||KEVtotal||0.0900||0 | ||
+ | |- | ||
+ | |'''Green Electricity (Mix Water - Wind 75/25)'''||1.25||''kA''||KEVtotal||0.0153||''kA'' | ||
+ | |- | ||
+ | |'''Strom '''||2.97(CH)||2||KEVtotal||0.155(CH)||0.15 | ||
|} | |} | ||
- | |||
===<u>'''Umrechnungsfaktoren für die Stromerzeugung (durchschnittliche nationale Stromerzeugung)'''</u>=== | ===<u>'''Umrechnungsfaktoren für die Stromerzeugung (durchschnittliche nationale Stromerzeugung)'''</u>=== | ||
- | + | Quelle: GEMIS 4.5 2005 Öko-Institut mit Ausnahme von PT: Source: DGGE 2008. <br> | |
+ | in <span style="color:red"> rot </span> Werte von GEMIS 4.8 für 2010 mit Ausnahme der CH | ||
{| class="wikitable" border="1" style="text-align:center;font-size:85%;width:45%" | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width:45%" | ||
|- | |- | ||
Zeile 602: | Zeile 1.041: | ||
! bgcolor="cccccc"|Conversion factor final energy to CO2 equivalents [kg/kWh] | ! bgcolor="cccccc"|Conversion factor final energy to CO2 equivalents [kg/kWh] | ||
|- | |- | ||
- | |AT||1,70||KEVtotal||0, | + | |AT||1,70||KEVtotal||0,278 |
|- | |- | ||
- | |BE||3,23||KEVtotal||0, | + | |BE||3,23||KEVtotal||0,289 |
|- | |- | ||
- | |BG||3,09||KEVtotal||0, | + | |BG||3,09||KEVtotal||0,557 |
|- | |- | ||
- | |CH||2, | + | |CH||<span style="color:red">2,97</span>||KEVtotal||<span style="color:red">0,155</span> |
|- | |- | ||
- | |CS||2,59||KEVtotal||0, | + | |CS||2,59||KEVtotal||0,944 |
|- | |- | ||
- | |CY||3,37||KEVtotal||0, | + | |CY||3,37||KEVtotal||0,947 |
|- | |- | ||
- | |CZ||3,06||KEVtotal||0, | + | |CZ||3,06||KEVtotal||0,785 |
|- | |- | ||
- | |DE||2,88||KEVtotal||0, | + | |DE||2,88||KEVtotal||<span style="color:red">0,562</span> |
|- | |- | ||
- | |DK||3,03||KEVtotal||0, | + | |DK||3,03||KEVtotal||0,666 |
|- | |- | ||
- | |EE||2,70||KEVtotal|| | + | |EE||2,70||KEVtotal||1,030 |
|- | |- | ||
- | |ES||2,45||KEVtotal||0, | + | |ES||2,45||KEVtotal||0,478 |
|- | |- | ||
- | |FI||3,48||KEVtotal||0, | + | |FI||3,48||KEVtotal||0,410 |
|- | |- | ||
- | |FR||3,35||KEVtotal||0, | + | |FR||3,35||KEVtotal||0,101 |
|- | |- | ||
- | |GB||2,65||KEVtotal||0, | + | |GB||2,65||KEVtotal||0,530 |
|- | |- | ||
- | |GR||2,56||KEVtotal||0, | + | |GR||2,56||KEVtotal||0,841 |
|- | |- | ||
- | |HR||2,32||KEVtotal||0, | + | |HR||2,32||KEVtotal||0,639 |
|- | |- | ||
- | |HU||3,16||KEVtotal||0, | + | |HU||3,16||KEVtotal||0,447 |
|- | |- | ||
- | |IE||2,33||KEVtotal||0, | + | |IE||2,33||KEVtotal||0,653 |
|- | |- | ||
- | |IT||2,37||KEVtotal||0, | + | |IT||2,37||KEVtotal||0,563 |
|- | |- | ||
- | |LT||3,62||KEVtotal||0, | + | |LT||3,62||KEVtotal||0,409 |
|- | |- | ||
- | |LU||2,14||KEVtotal||0, | + | |LU||2,14||KEVtotal||0,416 |
|- | |- | ||
- | |LV||2,07||KEVtotal||0, | + | |LV||2,07||KEVtotal||0,315 |
|- | |- | ||
- | |MD||2,36||KEVtotal||0, | + | |MD||2,36||KEVtotal||0,509 |
|- | |- | ||
- | |MT||3,38||KEVtotal||0, | + | |MT||3,38||KEVtotal||0,949 |
|- | |- | ||
- | |NL||2,73||KEVtotal||0, | + | |NL||2,73||KEVtotal||0,595 |
|- | |- | ||
- | |NO||1,04||KEVtotal||0, | + | |NO||1,04||KEVtotal||0,014 |
|- | |- | ||
- | |PL||2,71||KEVtotal||0, | + | |PL||2,71||KEVtotal||0,977 |
|- | |- | ||
- | |PT|| | + | |PT||2,72||KEVtotal||0,684 |
|- | |- | ||
- | |RO||2,62||KEVtotal||0, | + | |RO||2,62||KEVtotal||0,605 |
|- | |- | ||
- | |RU||2,91||KEVtotal||0, | + | |RU||2,91||KEVtotal||0,588 |
|- | |- | ||
- | |SE||2,48||KEVtotal||0, | + | |SE||2,48||KEVtotal||0,088 |
|- | |- | ||
- | |SI||2,93||KEVtotal||0, | + | |SI||2,93||KEVtotal||0,134 |
|- | |- | ||
- | |SK||3,09||KEVtotal||0, | + | |SK||3,09||KEVtotal||0,350 |
|- | |- | ||
- | |TR||2, | + | |TR||<span style="color:red">2,15</span>||KEVtotal||<span style="color:red">0,586</span> |
|- | |- | ||
- | |UA||3, | + | |UA||<span style="color:red">3,46</span>||KEVtotal||<span style="color:red">0,675</span> |
+ | |- | ||
+ | |<span style="color:red">China</span>||<span style="color:red">2,33</span>||KEVtotal||<span style="color:red">0,790</span> | ||
|} | |} | ||
<br/> | <br/> | ||
- | ===<u>'''Umrechungsfaktoren für die Stromerzeugung (spezifische Energiequellen) '''</u>=== | + | ===<u>''' Umrechungsfaktoren für die Stromerzeugung (spezifische Energiequellen)'''</u>=== |
Quelle: GEMIS 4.3 2004 Öko-Institut | Quelle: GEMIS 4.3 2004 Öko-Institut | ||
Zeile 688: | Zeile 1.129: | ||
|Elekrtizität (erneuerbar, Mix aus Wasser 50%/Wind 50%)||1,05||KEV(nonrenewable+renewable)||0,0295 | |Elekrtizität (erneuerbar, Mix aus Wasser 50%/Wind 50%)||1,05||KEV(nonrenewable+renewable)||0,0295 | ||
|} | |} | ||
- | + | <br/> | |
- | + | <br/> | |
- | + | ===<u>'''Nationaler Energiemix (nach Ländern geordnet)'''</u>=== | |
- | + | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width:40%" | |
- | + | |- | |
- | '''Nationaler Energiemix(nach Ländern geordnet) '''< | + | ! bgcolor="cccccc"|Country |
- | + | ! bgcolor="cccccc"|Country code | |
+ | ! bgcolor="cccccc"|Fossils | ||
+ | ! bgcolor="cccccc"|Nuclear | ||
+ | ! bgcolor="cccccc"|Renewables | ||
+ | ! bgcolor="cccccc"|Source | ||
+ | |- | ||
+ | ||Austria||AT||33%||0%||67%||IEA 2011 | ||
+ | |- | ||
+ | ||Belgium||BE||37%||53%||10%||IEA 2011 | ||
+ | |- | ||
+ | ||Bulgaria||BG||59%||32%||9%||IEA 2011 | ||
+ | |- | ||
+ | ||Switzerland||CH||5%||41%||54%||IEA 2011 | ||
+ | |- | ||
+ | ||Serbia||CS||76%||0%||24%||IEA 2011 | ||
+ | |- | ||
+ | ||Cyprus||CY||96%||0%||4%||IEA 2011 | ||
+ | |- | ||
+ | ||Czech Republic||CZ||59%||32%||9%||IEA 2011 | ||
+ | |- | ||
+ | ||Germany||DE||61%||18%||21%||IEA 2011 | ||
+ | |- | ||
+ | ||Denmark||DK||62%||0%||38%||IEA 2011 | ||
+ | |- | ||
+ | ||Estonia||EE||91%||0%||9%||IEA 2011 | ||
+ | |- | ||
+ | ||Spain||ES||50%||20%||30%||IEA 2011 | ||
+ | |- | ||
+ | ||Finland||FI||36%||32%||33%||IEA 2011 | ||
+ | |- | ||
+ | ||France||FR||9%||79%||12%||IEA 2011 | ||
+ | |- | ||
+ | ||United Kingdom||GB||72%||19%||10%||IEA 2011 | ||
+ | |- | ||
+ | ||Greece||GR||86%||0%||14%||IEA 2011 | ||
+ | |- | ||
+ | ||Croatia||HR||55%||0%||45%||IEA 2011 | ||
+ | |- | ||
+ | ||Hungary||HU||49%||44%||7%||IEA 2011 | ||
+ | |- | ||
+ | ||Ireland||IE||80%||0%||20%||IEA 2011 | ||
+ | |- | ||
+ | ||Italy||IT||72%||0%||28%||IEA 2011 | ||
+ | |- | ||
+ | ||Lithuania||LT||60%||0%||40%||IEA 2011 | ||
+ | |- | ||
+ | ||Luxembourg||LU||66%||0%||34%||IEA 2011 | ||
+ | |- | ||
+ | ||Latvia||LV||50%||0%||50%||IEA 2011 | ||
+ | |- | ||
+ | ||Moldova||MD||94%||0%||6%||IEA 2011 | ||
+ | |- | ||
+ | ||Malta||AT||99.6%||0%||0.4%||IEA 2011 | ||
+ | |- | ||
+ | ||Netherlands||NL||87%||4%||9%||IEA 2011 | ||
+ | |- | ||
+ | ||Norway||NO||3%||0%||97%||IEA 2011 | ||
+ | |- | ||
+ | ||Poland||PL||92%||0%||8%||IEA 2011 | ||
+ | |- | ||
+ | ||Portugal||PT||53%||0%||47%||IEA 2011 | ||
+ | |- | ||
+ | ||Romania||RO||55%||19%||27%||IEA 2011 | ||
+ | |- | ||
+ | ||Russia||RU||68%||16%||16%||IEA 2011 | ||
+ | |- | ||
+ | ||Sweden||SE||5%||40%||55%||IEA 2011 | ||
+ | |- | ||
+ | ||Slovenia||SI||36%||39%||25%||IEA 2011 | ||
+ | |- | ||
+ | ||Slovakia||SK||27%||54%||19%||IEA 2011 | ||
+ | |- | ||
+ | ||Turquey||TR||75%||0%||25%||IEA 2011 | ||
+ | |- | ||
+ | ||Ukraine||UA||48%||46%||6%||IEA 2011 | ||
+ | |- | ||
+ | ||China||CN||81%||2%||17%||IEA 2011 | ||
+ | |- | ||
+ | |} | ||
+ | <br/> | ||
===<u>'''Umrechnungsfaktoren für Fernwärme (Voreinstellungen)'''</u>=== | ===<u>'''Umrechnungsfaktoren für Fernwärme (Voreinstellungen)'''</u>=== | ||
- | [[ | + | {| class="wikitable" border="1" style="text-align:center;font-size:85%;width: 70%" |
+ | |- | ||
+ | ! | | ||
+ | ! bgcolor="cccccc"|Energie oder Energiequelle [kWh/kWh] | ||
+ | ! bgcolor="cccccc"|Art des Umrechnungsfaktors | ||
+ | ! bgcolor="cccccc"|Umrechnungsfaktor Endenergie zu CO2-Aquivalente[kg/kWh] | ||
+ | ! bgcolor="cccccc"|Quelle | ||
+ | |- | ||
+ | |Fernwärme produziert in einem Heizkraftwerk mit Kraft-Wärme-Kopplungsanlage||0,78||CEDtotal||0,24||GEMIS version 4.14 calculation made by the IWU, 2004, 70 % cogeneration | ||
+ | |- | ||
+ | |Fernwärme, produziert im Heizwerk (ohne Kraft-Wärme-Kopplungsanlage)||1,49||CEDtotal||0,41||GEMIS version 4.14 calculation made by the IWU, 2004 | ||
+ | |} | ||
+ | <br/> |
Aktuelle Version vom 12:06, 15. Okt. 2014
Klassifikationsschema
Die dänische Klassifikation, die seit 1996 Verwendung findet, bildet die Grundlage für die Display®-Klassifikation. Derzeit ist das dänische Zertifizierungssystem, das eine umfassende Gebäudetypologie einbezieht, noch das einzige seiner Art in Europa.
Ein iterativer Ansatzes mit einer höheren Anzahl registrierter Gebäude in den verschiedenen Gebäudekategorien und ermöglichte es, die Klassifikation nach den ersten sechs Monaten schrittweise zu verfeinern.
Ferner wird das Klassifikationsschema die Informationen einbeziehen, die von der Arbeitsgruppe „Concerted Action“ (CA) zur Verfügung gestellt werden. Diese Arbeitsgruppe, die aus Vertretern fast aller EU-Staaten besteht, arbeitet an der Harmonisierung und Einführung der Gebäuderichtlinie für den Energiepass.
Gegenwärtig können 11 Gebäudekategorien klassifiziert werden. Aufgrund von ständigen Verbesserungen kann das Schema sich in Zukunft noch ändern.
Klassifikationsschema Display® für die Primärenergiekennzahl
kWh/(m².yr) | 1/ Kindergarten | 2/ Allgemeinbildende Schule | 3/ Berufsschule | 4/ Verwaltungs-gebäude | 5/ Schwimmhalle | 6/ Sporthalle | 7/ Depot / Betriebshof | 8/ Soziokulturelles Gebäude |
---|---|---|---|---|---|---|---|---|
A | X ≤ 75 | X ≤ 50 | X ≤ 75 | X ≤ 75 | X ≤ 500 | X ≤ 75 | X ≤ 75 | X ≤ 75 |
B | 75 < X ≤ 140 | 50 < X ≤ 100 | 125 < X ≤ 175 | 75 < X ≤ 140 | 500 < X ≤ 2000 | 75 < X ≤ 150 | 75 < X ≤ 160 | 75 < X ≤ 160 |
C | 140 < X ≤ 205 | 100 < X ≤ 150 | 125 < X ≤ 175 | 140 < X ≤ 205 | 2000 < X ≤ 3500 | 150 < X ≤ 225 | 160 < X ≤ 245 | 160 < X ≤ 245 |
D | 205 < X ≤ 270 | 150 < X ≤ 200 | 175 < X ≤ 225 | 205 < X ≤ 270 | 3500 < X ≤ 5000 | 225 < X ≤ 300 | 245 < X ≤ 330 | 245 < X ≤ 330 |
E | 270 < X ≤ 335 | 200 < X ≤ 250 | 225 < X ≤ 275 | 270 < X ≤ 335 | 5000 < X ≤ 6500 | 300 < X ≤ 375 | 330 < X ≤ 415 | 330 < X ≤ 415 |
F | 335 < X ≤ 400 | 250 < X ≤ 300 | 275 < X ≤ 325 | 335 < X ≤ 400 | 6500 < X ≤ 8000 | 375 < X ≤ 420 | 415 < X ≤ 500 | 415 < X ≤ 500 |
G | X > 400 | X > 300 | X > 325 | X > 400 | X > 8000 | X > 450 | X > 500 | X > 500 |
kWh/(m².yr) | 9/ Heim | 10/ Gebäude der öffentlichen Sicherheit | 11/ Mehrfamilienhaus | 12/ Ein-/Zweifamilienhaus | 13/ Verkaufsstätte | 14/ Restaurant | 15/ Industriegebäude | 16/ Krankenhaus |
---|---|---|---|---|---|---|---|---|
A | X ≤ 150 | X ≤ 100 | X ≤ 50 | X ≤ 50 | X ≤ 75 | X ≤ 125 | X ≤ 50 | X ≤ 175 |
B | 150 < X ≤ 225 | 100 < X ≤ 200 | 50 < X ≤ 100 | 50 < X ≤ 110 | 75 < X ≤ 145 | 125 < X ≤ 245 | 50 < X ≤ 100 | 175 < X ≤ 300 |
C | 225 < X ≤ 300 | 200 < X ≤ 300 | 100 < X ≤ 150 | 110 < X ≤ 170 | 145 < X ≤ 215 | 245 < X ≤ 365 | 100 < X ≤ 150 | 300 < X ≤ 425 |
D | 300 < X ≤ 375 | 300 < X ≤ 400 | 150 < X ≤ 200 | 170 < X ≤ 230 | 215 < X ≤ 285 | 365 < X ≤ 485 | 150 < X ≤ 200 | 425 < X ≤ 550 |
E | 375 < X ≤ 450 | 400 < X ≤ 500 | 200 < X ≤ 250 | 230 < X ≤ 290 | 285 < X ≤ 355 | 485 < X ≤ 605 | 200 < X ≤ 250 | 550 < X ≤ 675 |
F | 450 < X ≤ 525 | 500 < X ≤ 600 | 250 < X ≤ 300 | 290 < X ≤ 350 | 335 < X ≤ 425 | 605 < X ≤ 725 | 250 < X ≤ 300 | 675 < X ≤ 800 |
G | X > 525 | X > 600 | X > 300 | X > 350 | X > 425 | X > 725 | X > 300 | X > 800 |
Klassifikationsschema für die Primärenergiekennzahl nach GEAK (Schweiz)
Klassifikation GEAK
kWh/(m².an) | Mehrfamilienhaus (I) | Ein-/Zweifamilienhaus (II) | Verwaltung (III) | Schule(IV) | Verkaufsstätte (IV) | Restaurant (VI) |
---|---|---|---|---|---|---|
entsprechender Gebäudetyp Display® | Mehrfamilienhaus (11) | Ein-/Zweifamilienhaus (12) | Verwaltung (4) | Kindergarten (1) Allgemeinbildende Schule (2) | Verkaufsstätte (13) | Restaurant (14) |
A | X ≤ 59 | X ≤ 56 | X ≤ 46 | X ≤ 36 | X ≤ 53 | X ≤ 96 |
B | 59 < X ≤ 118 | 56 < X ≤ 113 | 46 < X ≤ 92 | 36 < X ≤ 71 | 53 < X ≤ 105 | 96 < X ≤ 191 |
C | 118 < X ≤ 177 | 113 < X ≤ 169 | 92 < X ≤ 138 | 71 < X ≤ 107 | 105 < X ≤ 158 | 191 < X ≤ 287 |
D | 177 < X ≤ 237 | 169 < X ≤ 226 | 138 < X ≤ 184 | 107 < X ≤ 142 | 158 < X ≤ 210 | 287 < X ≤ 382 |
E | 237 < X ≤ 296 | 226 < X ≤ 282 | 184 < X ≤ 231 | 142 < X ≤ 178 | 210 < X ≤ 263 | 382 < X ≤ 478 |
F | 296 < X ≤ 355 | 282 < X ≤ 338 | 231 < X ≤ 277 | 178 < X ≤ 213 | 263 < X ≤ 315 | 478 < X ≤ 573 |
G | X > 355 | X > 338 | X > 277 | X > 213 | X > 315 | X > 573 |
Klassifikation GEAK
kWh/(m².an) | Soziales/Kulturelles Gebäude (VII) | Krankenhaus (VIII) | Industrie (IX) | Dépôt/Betriebshof (X) | Sporthalle (XI) | Hallenbad (XII) |
---|---|---|---|---|---|---|
entsprechender Gebäudetyp Display® | Soziales/Kulturelles Gebäude (8) | Krankenhaus(9) | Industrie (15) Gesundheitswesen (10) | Dépôt/Betriebshof (7) | Sporthalle (6) | Hallenbad (5) |
A | X ≤ 50 | X ≤ 64 | X ≤ 38 | X ≤ 22 | X ≤ 76 | X ≤ 130 |
B | 50 < X ≤ 99 | 64 < X ≤ 128 | 38 < X ≤ 76 | 22 < X ≤ 43 | 76 < X ≤ 151 | 130 < X ≤ 259 |
C | 99 < X ≤ 149 | 128 < X ≤ 192 | 76 < X ≤ 114 | 43 < X ≤ 65 | 151 < X ≤ 227 | 259 < X ≤ 389 |
D | 149 < X ≤ 198 | 192 < X ≤ 256 | 114 < X ≤ 152 | 65 < X ≤ 86 | 227 < X ≤ 302 | 389 < X ≤ 518 |
E | 198 < X ≤ 248 | 256 < X ≤ 320 | 152 < X ≤ 190 | 86 < X ≤ 108 | 302 < X ≤ 378 | 518 < X ≤ 648 |
F | 248 < X ≤ 297 | 320 < X ≤ 384 | 190 < X ≤ 228 | 108 < X ≤ 129 | 378 < X ≤ 453 | 648 < X ≤ 777 |
G | X > 297 | X > 384 | X > 228 | X > 129 | X > 453 | X > 777 |
Klassifikationsschema Display® für die CO2-Kennzahl
kg/(m².yr) | 1/ Kindergarten | 2/ Allgemeinbildende Schule | 3/ Berufsschule | 4/ Verwaltungs-gebäude | 5/ Schwimmhalle | 6/ Sporthalle | 7/ Depot / Betriebshof | 8/ Soziokulturelles Gebäude |
---|---|---|---|---|---|---|---|---|
A | X ≤ 15 | X ≤ 10 | X ≤ 15 | X ≤ 15 | X ≤ 100 | X ≤ 15 | X ≤ 15 | X ≤ 15 |
B | 15 < X ≤ 28 | 10 < X ≤ 20 | 15 < X ≤ 25 | 15 < X ≤ 28 | 100 < X ≤ 400 | 15 < X ≤ 30 | 15 < X ≤ 32 | 15 < X ≤ 32 |
C | 28 < X ≤ 41 | 20 < X ≤ 30 | 25 < X ≤ 35 | 28 < X ≤ 41 | 400 < X ≤ 700 | 30 < X ≤ 45 | 32 < X ≤ 49 | 32 < X ≤ 49 |
D | 41 < X ≤ 54 | 30 < X ≤ 40 | 35 < X ≤ 45 | 41 < X ≤ 54 | 700 < X ≤ 1000 | 45 < X ≤ 60 | 49 < X ≤ 66 | 49 < X ≤ 66 |
E | 54 < X ≤ 67 | 40 < X ≤ 50 | 45 < X ≤ 55 | 54 < X ≤ 67 | 1000 < X ≤ 1300 | 60 < X ≤ 75 | 66 < X ≤ 83 | 66 < X ≤ 83 |
F | 67 < X ≤ 80 | 50 < X ≤ 60 | 55 < X ≤ 65 | 67 < X ≤ 80 | 1300 < X ≤ 1600 | 75 < X ≤ 90 | 83 < X ≤ 100 | 83 < X ≤ 100 |
G | X > 80 | X > 60 | X > 65 | X > 80 | X > 1600 | X > 90 | X > 100 | X > 100 |
kg/(m².yr) | 9/ Heim | 10/ Gebäude der öffentlichen Sicherheit | 11/ Mehrfamilienhaus | 12/ Ein-/Zweifamilienhaus | 13/ Verkaufsstätte | 14/ Restaurant | 15/ Industriegebäude | 16/ Krankenhaus |
---|---|---|---|---|---|---|---|---|
A | X ≤ 30 | X ≤ 20 | X ≤ 10 | X ≤ 10 | X ≤ 15 | X ≤ 25 | X ≤ 10 | X ≤ 35 |
B | 30 < X ≤ 45 | 20 < X ≤ 36 | 10 < X ≤ 20 | 10 < X ≤ 22 | 15 < X ≤ 29 | 25 < X ≤ 49 | 10 < X ≤ 20 | 35 < X ≤ 60 |
C | 45 < X ≤ 60 | 36 < X ≤ 52 | 20 < X ≤ 30 | 22 < X ≤ 34 | 29 < X ≤ 43 | 49 < X ≤ 73 | 20 < X ≤ 30 | 60 < X ≤ 85 |
D | 60 < X ≤ 75 | 52 < X ≤ 68 | 30 < X ≤ 40 | 34 < X ≤ 46 | 43 < X ≤ 57 | 73 < X ≤ 97 | 30 < X ≤ 40 | 85 < X ≤ 110 |
E | 75 < X ≤ 90 | 68 < X ≤ 86 | 40 < X ≤ 50 | 46 < X ≤ 58 | 57 < X ≤ 71 | 97 < X ≤ 121 | 40 < X ≤ 50 | 110 < X ≤ 135 |
F | 90 < X ≤ 105 | 86 < X ≤ 102 | 50 < X ≤ 60 | 58 < X ≤ 70 | 71 < X ≤ 85 | 121 < X ≤ 145 | 50 < X ≤ 60 | 135 < X ≤ 160 |
G | X > 105 | X > 102 | X > 60 | X > 70 | X > 85 | X > 145 | X > 60 | X > 160 |
Klassifikationsschema für die CO2-Kennzahl Version GEAK(Schweiz)
Klassifikation GEAK
kg/(m².an) | Mehrfamilienhaus (I) | Ein-/Zweifamilienhaus (II) | Verwaltung (III) | Schule(IV) | Verkaufsstätte (IV) | Restaurant (VI) |
---|---|---|---|---|---|---|
entsprechender Gebäudetyp Display® | Mehrfamilienhaus (11) | Ein-/Zweifamilienhaus (12) | Verwaltung (4) | Kindergarten (1) Allgemeinbildende Schule (2) | Verkaufsstätte (13) | Restaurant (14) |
A | X ≤ 15 | X ≤ 14 | X ≤ 12 | X ≤ 9 | X ≤ 14 | X ≤ 23 |
B | 15 < X ≤ 29 | 14 < X ≤ 27 | 12 < X ≤ 23 | 9 < X ≤ 17 | 14 < X ≤ 27 | 23 < X ≤ 46 |
C | 29 < X ≤ 44 | 27 < X ≤ 41 | 23 < X ≤ 35 | 9 < X ≤ 26 | 14 < X ≤ 41 | 23 < X ≤ 69 |
D | 44 < X ≤ 58 | 41 < X ≤ 54 | 35 < X ≤ 46 | 26 < X ≤ 34 | 41 < X ≤ 54 | 69 < X ≤ 92 |
E | 58 < X ≤ 73 | 54 < X ≤ 68 | 46 < X ≤ 58 | 34 < X ≤ 43 | 54 < X ≤ 68 | 92 < X ≤ 115 |
F | 73 < X ≤ 87 | 68 < X ≤ 81 | 58 < X ≤ 69 | 43 < X ≤ 51 | 68 < X ≤ 81 | 115 < X ≤ 138 |
G | X > 87 | X > 81 | X > 69 | X > 51 | X > 81 | X > 138 |
KlassifiKation GEAK
kg/(m².an) | Soziales/Kulturelles Gebäude (VII) | Krankenhaus (VIII) | Industrie (IX) | Dépôt/Betriebshof (X) | Sporthalle (XI) | Hallenbad (XII) |
---|---|---|---|---|---|---|
entsprechender Gebäudetyp Display® | Soziales/Kulturelles Gebäude (8) | Krankenhaus(9) | Industrie (15) Gesundheitswesen (10) | Dépôt/Betriebshof (7) | Sporthalle (6) | Hallenbad (5) |
A | X ≤ 12 | X ≤ 16 | X ≤ 10 | X ≤ 5 | X ≤ 17 | X ≤ 31 |
B | 12 < X ≤ 24 | 16 < X ≤ 31 | 10 < X ≤ 19 | 5 < X ≤ 10 | 17 < X ≤ 34 | 31 < X ≤ 62 |
C | 24 < X ≤ 36 | 31 < X ≤ 47 | 19 < X ≤ 29 | 10 < X ≤ 15 | 34 < X ≤ 51 | 62 < X ≤ 93 |
D | 36 < X ≤ 48 | 47 < X ≤ 62 | 29 < X ≤ 38 | 15 < X ≤ 20 | 51 < X ≤ 68 | 93 < X ≤ 124 |
E | 48 < X ≤ 60 | 62 < X ≤ 78 | 38 < X ≤ 48 | 20 < X ≤ 25 | 68 < X ≤ 85 | 124 < X ≤ 155 |
F | 60 < X ≤ 72 | 78 < X ≤ 93 | 48 < X ≤ 57 | 25 < X ≤ 30 | 85 < X ≤ 102 | 155 < X ≤ 186 |
G | X > 72 | X > 93 | X > 57 | X > 30 | X > 102 | X > 186 |
Klassifikationsschema für die Wasserkennzahl
L/(m².yr) | 1/ Kindergarten | 2/ Allgemeinbildende Schule | 2/Schule mit Schwimmbad(L/m² Beckenoberfläche) | 3/ Berufsschule | 4/ Verwaltungs-gebäude | 5/ Schwimmhalle | 6/ Sporthalle | 7/ Depot / Betriebshof | 8/ Soziokulturelles Gebäude |
---|---|---|---|---|---|---|---|---|---|
A | X ≤ 50 | X ≤ 60 | X ≤ 12500 | X ≤ 50 | X ≤ 30 | X ≤ 80 | X ≤ 40 | X ≤ 30 | X ≤ 30 |
B | 50 < X ≤ 250 | 60 < X ≤ 150 | 12500 < X ≤ 25000 | 50 < X ≤ 145 | 30 < X ≤ 170 | 80 < X ≤ 125 | 40 < X ≤ 110 | 30 < X ≤ 110 | 30 < X ≤ 100 |
C | 250 < X ≤ 450 | 150 < X ≤ 240 | 25000 < X ≤ 37500 | 145 < X ≤ 240 | 170 < X ≤ 240 | 125 < X ≤ 170 | 110 < X ≤ 180 | 110 < X ≤ 190 | 100 < X ≤ 170 |
D | 450 < X ≤ 650 | 240 < X ≤ 330 | 37500 < X ≤ 50000 | 240 < X ≤ 335 | 240 < X ≤ 310 | 170 < X ≤ 215 | 180 < X ≤ 250 | 190 < X ≤ 270 | 170 < X ≤ 240 |
E | 650 < X ≤ 850 | 330 < X ≤ 420 | 50000 < X ≤ 62500 | 335 < X ≤ 430 | 310 < X ≤ 380 | 215 < X ≤ 260 | 250 < X ≤ 320 | 270 < X ≤ 350 | 240 < X ≤ 310 |
F | 850 < X ≤ 1050 | 420 < X ≤ 510 | 62500 < X ≤ 75000 | 430 < X ≤ 525 | 380 < X ≤ 450 | 260 < X ≤ 305 | 320 < X ≤ 390 | 350 < X ≤ 430 | 310 < X ≤ 380 |
G | X > 1050 | X > 510 | X > 75000 | X > 525 | X > 450 | X > 305 | X > 390 | X > 430 | X > 380 |
L/(m².yr) | 9/ Heim | 10/ Gebäude der öffentlichen Sicherheit | 11/ Mehrfamilienhaus | 12/ Ein-/Zweifamilienhaus | 13/ Verkaufsstätte | 14/ Restaurant | 15/ Industriegebäude | 16/ Krankenhaus |
---|---|---|---|---|---|---|---|---|
A | X ≤ 80 | X ≤ 350 | X ≤ 300 | X ≤ 500 | X ≤ 100 | X ≤ 500 | X ≤ 350 | X ≤ 500 |
B | 80 < X ≤ 510 | 350 < X ≤ 500 | 300 < X ≤ 550 | 500 < X ≤ 800 | 100 < X ≤ 200 | 500 < X ≤ 750 | 350 < X ≤ 480 | 500 < X ≤ 750 |
C | 510 < X ≤ 940 | 500 < X ≤ 650 | 550 < X ≤ 800 | 800 < X ≤ 1100 | 200 < X ≤ 300 | 750 < X ≤ 1000 | 480 < X ≤ 610 | 750 < X ≤ 1000 |
D | 940 < X ≤ 1380 | 650 < X ≤ 800 | 800 < X ≤ 1050 | 1100 < X ≤ 1400 | 300 < X ≤ 400 | 1000 < X ≤ 1250 | 610 < x ≤ 740 | 1000 < x ≤ 1250 |
E | 1380 < X ≤ 1810 | 800 < X ≤ 950 | 1050 < X ≤ 1300 | 1400 < X ≤ 1700 | 400 < X ≤ 500 | 1250 < X ≤ 1500 | 740 < X ≤ 870 | 1250 < X ≤ 1500 |
F | 1810 < X ≤ 2240 | 950 < X ≤ 1100 | 1300 < X ≤ 1550 | 1700 < X ≤ 2000 | 500 < X ≤ 600 | 1500 < X ≤ 1750 | 870 < X ≤ 1000 | 1500 < X ≤ 1750 |
G | X > 2240 | X > 1100 | X > 1550 | X > 2000 | X > 600 | X > 1750 | X > 1000 | X > 1750 |
Klassifikationsschema für die Raumtemperatur in C°
kWh/(m².yr) | Building Type 1/2/3/4/8/9/11/12 | Building Type 6/13/15 | Building Type 10/16 | Building Type 5 | Building Type 14 |
---|---|---|---|---|---|
A | 19° ≤ X< 20° | 17,5° ≤ X< 18,5° | 21,5° ≤ X< 22,5° | 27,5° ≤ X< 28,5° | 20,5° ≤ X< 21,5° |
B | 18,5° ≤ X < 19,0° or 20,0° ≤ X< 21,0° | 17,0° ≤ X < 17,5° or 18,5° ≤ X< 19,5° | 21,0° ≤ X < 21,5° or 22,5° ≤ X< 23,5° | 27,0° ≤ X < 27,5° or 28,5° ≤ X< 29,5° | 20,0° ≤ X < 20,5° or 21,5° ≤ X< 22,5° |
C | 18,0° ≤ X < 18,5° Or 21,0° ≤ X< 22,0° | 16,5° ≤ X < 17,0° or 19,5° ≤ X< 20,5° | 20,5° ≤ X < 21,0° or 23,5° ≤ X< 24,5° | 26,5° ≤ X < 27,0° Or 29,5° < X ≤ 30,5° | 19,5° ≤ X < 20,0° Or 22,5° < X ≤ 23,5° |
D | 17,5° ≤ X < 18,0° OR 22,0° ≤ X< 23,0° | 16,0° ≤ X < 16,5° or 20,5° ≤ X< 21,5° | 20,0° ≤ X < 20,5° or 24,5° ≤ X< 25,5° | 26,0° ≤ X < 27,5° OR 30,5° < X ≤ 31,5° | 19,0° ≤ X < 19,5° OR 23,5° < X ≤ 24,5° |
E | 17,0° ≤ X < 17,5° OR 23,0° ≤ X< 24,0° | 15,5° ≤ X < 16,0° or 21,5° ≤ X< 22,5° | 19,5° ≤ X < 20,0° or 25,5° ≤ X< 26,5° | 25,5° ≤ X < 26,0° OR 31,5° < X ≤ 32,5° | 18,5° ≤ X < 19,0° OR 24,5° < X ≤ 25,5° |
F | 16,5° ≤ X < 17,0° OR 24,0° ≤ X< 25,0° | 15,0° ≤ X < 15,5° or 22,5° ≤ X< 23,5° | 19,0° ≤ X < 19,5° or 26,5° ≤ X< 27,5° | 25,0° ≤ X < 25,5° OR 32,5° < X ≤ 33,5° | 18,0° ≤ X < 18,5° OR 25,5° < X ≤ 26,5° |
G | 16,0° < X > 25,0° | 15,0° < X > 23,5° | 19,0° < X > 27,5° | 25,0° < X > 33,5° | 18,0° < X > 26,5° |
Gebäudetypen:
- 1: Kindergarten
- 2-3 : Allgemeinbildende Schule und Berufsschule
- 4 : Verwaltungsgebäude
- 5 : Swimmhalle
- 6 : Sporthalle
- 7 : Depot/Betriebshof
- 8 : Soziokulturelles Gebäude
- 9 : Heim
- 10 : Gebäude der öffentlichen Sicherheit
- 11-12: Mehrfamilienhaus oder Ein-/Zweifamilienhaus
- 13 : Verkaufsstätte
- 14 : Restaurant
- 15 : Industriegebäude
- 16 : Krankenhaus
Klassifikationsschema für die Raumluftqualität
kWh/(m².yr) | Indoor Air quality (ppm) All Building types |
---|---|
A | X ≤ 750 |
B | 750 < X ≤ 900 |
C | 900 < X ≤ 1200 |
D | 1200 < X ≤ 1500 |
E | 1500 < X ≤ 1800 |
F | 1800 < X ≤ 2100 |
G | X > 2100 |
Umrechnungsfaktoren und ihre Quellen
Allgemeine Umrechnungsfaktoren
Energie oder Energiquellen | Art dem Umrechnung | Umrechnungsfaktor | Einheit |
---|---|---|---|
MWh to kWh | 1000 | kWh/MWh | |
kWh to MWh | 0,001 | MWh/kWh | |
Holz (1) | kg to kWh | 5,5 | kWh/kg |
Steinkohle | kg to kWh | 8,6 | kWh/kg |
Braunkohle | kg to kWh | 5,4 | kWh/kg |
Heizöl (leichtes) | l to kWh | 10,0 | kWh/l |
Erdgas | m3 to kWh | 10,1 | kWh/m3 |
Erdgas | Heiz/Brennwert | 0,9 | |
Biogas | m3 to kWh | 6,0 | kWh/m3 |
Flüssiggas | m3 to kWh | 26,0 | kWh/m3 |
Flüssiggas | kg to kWh | 12,9 | kWh/kg |
Flüssiggas | Heiz/Brennwert | 0,9 |
(1) Source: Société suisse des ingénieurs et des architectes (SIA)
Umrechnungsfaktoren für den Energieträger
Umrechnungsfaktoren Endenergie zu Primärenergie nach der Display® bzw. GEAK Methodik
Energie oder Energiequelle (1) | Umrechnungsfaktor Endenergie zu Primärenergie [kWh/kWh] | Art des Umrechnungsfaktors | Umrechnunsfaktor Endenergie zu CO2-Aquivalente [kg/kWh] | ||
---|---|---|---|---|---|
Display/SIA 2031 (2009) | GEAK | Display | Display/SIA 2031 (2009) | GEAK | |
Erdgas | 1,15 | 1 | KEVtotal | 0,2400 | 0.24 |
Flüssiggas | 1,15 | kA | KEVtotal | 0,2400 | kA |
Heizöl | 1,24 | 1 | KEVtotal | 0,3000 | 0.3 |
Steinkohle | 1,19 | 1 | KEVtotal | 0,3900 | 0.43 |
Braunkohle | 1,66 | 1 | KEVtotal | 0,4300 | 0.43 |
Holzscheite | 1,06 | 0.7 | KEVtotal | 0,0100 | 0.01 |
Holzhackschnitzel | 1,14 | 0.7 | KEVtotal | 0,0100 | 0.01 |
Holzpellets | 1,22 | 0.7 | KEVtotal | 0,0400 | 0.01 |
Solarthermie | 1,17 | kA | KEVtotal | 0,0479 | kA |
PV - monocrystalline | 1.66 | 0 | KEVtotal | 0.0900 | 0 |
Green Electricity (Mix Water - Wind 75/25) | 1.25 | kA | KEVtotal | 0.0153 | kA |
Strom | 2.97(CH) | 2 | KEVtotal | 0.155(CH) | 0.15 |
Umrechnungsfaktoren für die Stromerzeugung (durchschnittliche nationale Stromerzeugung)
Quelle: GEMIS 4.5 2005 Öko-Institut mit Ausnahme von PT: Source: DGGE 2008.
in rot Werte von GEMIS 4.8 für 2010 mit Ausnahme der CH
Country code | Conversion factor final energy to primary energy [kWh/kWh] | Type of conversion factor | Conversion factor final energy to CO2 equivalents [kg/kWh] |
---|---|---|---|
AT | 1,70 | KEVtotal | 0,278 |
BE | 3,23 | KEVtotal | 0,289 |
BG | 3,09 | KEVtotal | 0,557 |
CH | 2,97 | KEVtotal | 0,155 |
CS | 2,59 | KEVtotal | 0,944 |
CY | 3,37 | KEVtotal | 0,947 |
CZ | 3,06 | KEVtotal | 0,785 |
DE | 2,88 | KEVtotal | 0,562 |
DK | 3,03 | KEVtotal | 0,666 |
EE | 2,70 | KEVtotal | 1,030 |
ES | 2,45 | KEVtotal | 0,478 |
FI | 3,48 | KEVtotal | 0,410 |
FR | 3,35 | KEVtotal | 0,101 |
GB | 2,65 | KEVtotal | 0,530 |
GR | 2,56 | KEVtotal | 0,841 |
HR | 2,32 | KEVtotal | 0,639 |
HU | 3,16 | KEVtotal | 0,447 |
IE | 2,33 | KEVtotal | 0,653 |
IT | 2,37 | KEVtotal | 0,563 |
LT | 3,62 | KEVtotal | 0,409 |
LU | 2,14 | KEVtotal | 0,416 |
LV | 2,07 | KEVtotal | 0,315 |
MD | 2,36 | KEVtotal | 0,509 |
MT | 3,38 | KEVtotal | 0,949 |
NL | 2,73 | KEVtotal | 0,595 |
NO | 1,04 | KEVtotal | 0,014 |
PL | 2,71 | KEVtotal | 0,977 |
PT | 2,72 | KEVtotal | 0,684 |
RO | 2,62 | KEVtotal | 0,605 |
RU | 2,91 | KEVtotal | 0,588 |
SE | 2,48 | KEVtotal | 0,088 |
SI | 2,93 | KEVtotal | 0,134 |
SK | 3,09 | KEVtotal | 0,350 |
TR | 2,15 | KEVtotal | 0,586 |
UA | 3,46 | KEVtotal | 0,675 |
China | 2,33 | KEVtotal | 0,790 |
Umrechungsfaktoren für die Stromerzeugung (spezifische Energiequellen)
Quelle: GEMIS 4.3 2004 Öko-Institut
Energie oder Energiequelle | Umrechnungsfaktor Endenergie zu Primärenergie [kWh/kWh] | Art des Umrechnungsfaktors | Umrechnunsfaktor Endenergie zu CO2-Aquivalente [kg/kWh] |
---|---|---|---|
Polycrystalline PV Zelle | 1,62 | KEV(nonrenewable+renewable) | 0,1660 |
Elekrtizität (erneuerbar, Mix aus Wasser 50%/Wind 50%) | 1,05 | KEV(nonrenewable+renewable) | 0,0295 |
Nationaler Energiemix (nach Ländern geordnet)
Country | Country code | Fossils | Nuclear | Renewables | Source |
---|---|---|---|---|---|
Austria | AT | 33% | 0% | 67% | IEA 2011 |
Belgium | BE | 37% | 53% | 10% | IEA 2011 |
Bulgaria | BG | 59% | 32% | 9% | IEA 2011 |
Switzerland | CH | 5% | 41% | 54% | IEA 2011 |
Serbia | CS | 76% | 0% | 24% | IEA 2011 |
Cyprus | CY | 96% | 0% | 4% | IEA 2011 |
Czech Republic | CZ | 59% | 32% | 9% | IEA 2011 |
Germany | DE | 61% | 18% | 21% | IEA 2011 |
Denmark | DK | 62% | 0% | 38% | IEA 2011 |
Estonia | EE | 91% | 0% | 9% | IEA 2011 |
Spain | ES | 50% | 20% | 30% | IEA 2011 |
Finland | FI | 36% | 32% | 33% | IEA 2011 |
France | FR | 9% | 79% | 12% | IEA 2011 |
United Kingdom | GB | 72% | 19% | 10% | IEA 2011 |
Greece | GR | 86% | 0% | 14% | IEA 2011 |
Croatia | HR | 55% | 0% | 45% | IEA 2011 |
Hungary | HU | 49% | 44% | 7% | IEA 2011 |
Ireland | IE | 80% | 0% | 20% | IEA 2011 |
Italy | IT | 72% | 0% | 28% | IEA 2011 |
Lithuania | LT | 60% | 0% | 40% | IEA 2011 |
Luxembourg | LU | 66% | 0% | 34% | IEA 2011 |
Latvia | LV | 50% | 0% | 50% | IEA 2011 |
Moldova | MD | 94% | 0% | 6% | IEA 2011 |
Malta | AT | 99.6% | 0% | 0.4% | IEA 2011 |
Netherlands | NL | 87% | 4% | 9% | IEA 2011 |
Norway | NO | 3% | 0% | 97% | IEA 2011 |
Poland | PL | 92% | 0% | 8% | IEA 2011 |
Portugal | PT | 53% | 0% | 47% | IEA 2011 |
Romania | RO | 55% | 19% | 27% | IEA 2011 |
Russia | RU | 68% | 16% | 16% | IEA 2011 |
Sweden | SE | 5% | 40% | 55% | IEA 2011 |
Slovenia | SI | 36% | 39% | 25% | IEA 2011 |
Slovakia | SK | 27% | 54% | 19% | IEA 2011 |
Turquey | TR | 75% | 0% | 25% | IEA 2011 |
Ukraine | UA | 48% | 46% | 6% | IEA 2011 |
China | CN | 81% | 2% | 17% | IEA 2011 |
Umrechnungsfaktoren für Fernwärme (Voreinstellungen)
Energie oder Energiequelle [kWh/kWh] | Art des Umrechnungsfaktors | Umrechnungsfaktor Endenergie zu CO2-Aquivalente[kg/kWh] | Quelle | |
---|---|---|---|---|
Fernwärme produziert in einem Heizkraftwerk mit Kraft-Wärme-Kopplungsanlage | 0,78 | CEDtotal | 0,24 | GEMIS version 4.14 calculation made by the IWU, 2004, 70 % cogeneration |
Fernwärme, produziert im Heizwerk (ohne Kraft-Wärme-Kopplungsanlage) | 1,49 | CEDtotal | 0,41 | GEMIS version 4.14 calculation made by the IWU, 2004 |