THE CLASSIFICATION SCHEME

From Display Documentation in English

(Difference between revisions)
Jump to: navigation, search
Andre (Talk | contribs)
(New page: ===The Classification Scheme=== The Danish classification, used since 1996, is the base of the Display® classification schemes. So far the Danish scheme, taking into account a building t...)
Newer edit →

Revision as of 14:58, 23 June 2008

The Classification Scheme

The Danish classification, used since 1996, is the base of the Display® classification schemes. So far the Danish scheme, taking into account a building typology, is the only classification all over Europe.
By increasing the number of registered buildings in the different types and considering the recommendations of the CEN (Normalization European Comity), an iterative approach allowed to adjust the classification schemes after the first 6 test months.
Furthermore, the classification scheme will take into account the information provided by the Concerted Action, a working group composed of representatives from nearly all EU member states. The objective of the CA working group is the harmonisation of the implementation of the Energy Performance of Buildings Directive.
Currently, 11 types of buildings can be classified. The classification scheme could change in the future.

Classification scheme for the primary energy ratio:

Class kWh/ (m².yr) Day nursery / Kindergarten General school Professional school Administrative Swimming pool Sports hall Depot Social Cultural Health Centre Rescue Centre Multi residential
A 75 ≤ X 75 ≤ X 75 ≤ X X ≤ 75 X ≤ 500 X ≤ 75 X ≤ 250 X ≤ 75 X ≤ 250 X ≤ 100 X ≤ 50
B 75 < X ≤ 145 75 < X ≤ 140 75 < X ≤ 145 75 < X ≤ 140 500 < X ≤ 2000 75 < X ≤ 150 250 < X ≤ 350 75 < X ≤ 160 250 < X ≤ 350 100 < X ≤ 140 50 < X ≤ 100
C 145< X ≤ 215 140 < X ≤ 205 145< X ≤ 215 140 < X ≤ 205 2000 < X ≤ 3500 150 < X ≤ 225 350 < X ≤ 450 160 < X ≤ 245 350 < X ≤ 450 140 < X ≤ 180 100 < X ≤ 150
D 215 < X ≤ 285 205 < X ≤ 270 215 < X ≤ 285 205 < X ≤ 270 3500 < X ≤ 5000 225 < X ≤ 300 450 < X ≤ 550 245 < X ≤ 330 450 < X ≤ 550 180 < X ≤ 220 150 < X ≤ 200
E 285 < X ≤ 355 270 < X ≤ 335 285 < X ≤ 355 270 < X ≤ 335 5000 < X ≤ 6500 300 < X ≤ 375 550 < X ≤ 650 330 < X ≤ 415 550< X ≤ 650 220 < X ≤ 260 200 < X ≤ 250
F 355 < X ≤ 425 335 < X ≤ 400 355 < X ≤ 425 335 < X ≤ 400 6500 < X ≤ 8000 375 < X ≤ 450 650 < X ≤ 750 415 < X ≤ 500 650 < X ≤ 750 260 < X ≤ 300 250 < X ≤ 300
G X > 425 X > 400 X > 425 X > 400 X > 8000 X > 450 X > 750 X > 500 X > 750 X > 300 X > 300

Table 1: Classification scheme for the primary energy ratio

Classification scheme for the CO2 ratio:

Class (kg/ (m².yr) Day nursery / Kindergarten General school Professional school Administrative Swimming pool Sports hall Depot Social-Cultural Health centre Rescue centre Multi-residential
A 15 ≤ X 15 ≤ X 15 ≤ X 15 ≤ X X ≤ 100 X ≤ 15 X ≤ 50 X ≤ 15 X ≤ 50 X ≤ 20 X ≤ 10
B 15 < X ≤ 29 15 < X ≤ 28 15 < X ≤ 29 15 < X ≤ 28 100 < X ≤ 300 15 < X ≤ 30 50 < X ≤ 70 15 < X ≤ 32 50 < X ≤ 70 20 < X ≤ 28 10 < X ≤ 20
C 29< X ≤ 43 28 < X ≤ 41 29< X ≤ 43 28 < X ≤ 41 300 < X ≤ 700 30 < X ≤ 45 70 < X ≤ 90 32 < X ≤ 49 70 < X ≤ 90 28 < X ≤ 36 20 < X ≤ 30
D 43 < X ≤ 57 41 < X ≤ 54 43 < X ≤ 57 41 < X ≤ 54 700 < X ≤ 1000 45 < X ≤ 60 70 < X ≤ 90 32 < X ≤ 49 70 < X ≤ 90 28 < X ≤ 36 20 < X ≤ 30
E 57 < X ≤ 71 54 < X ≤ 67 57 < X ≤ 71 54 < X ≤ 67 1000 < X ≤ 1300 60 < X ≤ 75 110< X ≤ 130 56 < X ≤ 73 110< X ≤ 130 44 < X ≤ 52 40 < X ≤ 50
F 71 < X ≤ 85 67 < X ≤ 80 71 < X ≤ 85 67 < X ≤ 80 1300 < X ≤ 1600 75 < X ≤ 90 130 < X ≤ 150 73 < X ≤ 90 130 < X ≤ 150 52 < X ≤ 60 50 < X ≤ 60
G X > 85 X > 80 X > 85 X > 80 X > 1600 X > 90 X > 150 X > 90 X > 150 X > 60 X > 60

Table 2: Classification scheme for the CO2 ratio

Classification for the water ratio:
Classification scheme for the CO2 ratio:

Class (kg/ (m².yr) Day nursery / Kindergarten General school Professional school Administrative Swimming pool Sports hall Depot Social-Cultural Health centre Rescue centre Multi-residential
A 200 ≤ X 100 ≤ X 125 ≤ X X ≤ 100 X ≤ 80 100 ≤ X X ≤ 350 X ≤ 50 X ≤ 500 X ≤ 350 X ≤ 500
B 200 < X ≤ 350 100 < X ≤ 225 125 < X ≤ 250 100 < X ≤ 200 80 < X ≤ 125 100 < X ≤ 225 350 < X ≤ 500 50 < X ≤ 125 500 < X ≤ 750 350 < X ≤ 500 500 < X ≤ 750
C 350 < X ≤ 500 225 < X ≤ 350 250 < X ≤ 375 200 < X ≤ 300 125 < X ≤ 170 225 < X ≤ 350 500 < X ≤ 650 125 < X ≤ 200 750 < X ≤ 1000 500 < X ≤ 650 750 < X ≤ 1000
D 500 < X ≤ 650 350 < X ≤ 475 375 < X ≤ 500 300 < X ≤ 400 170 < X ≤ 215 350 < X ≤ 475 650 < X ≤ 800 200 < X ≤ 275 1000 < X ≤ 1250 650 < X ≤ 800 1000 < X ≤ 1250
E 650 < X ≤ 800 475 < X ≤ 600 500 < X ≤ 625 400 < X ≤ 500 215 < X ≤ 260 475 < X ≤ 600 800 < X ≤ 950 275 < X ≤ 350 1250 < X ≤ 1500 800 < X ≤ 950 1250 < X ≤ 1500
F 800 < X ≤ 950 600 < X ≤ 725 625 < X ≤ 750 500 < X ≤ 600 260 < X ≤ 305 600 < X ≤ 725 950 < X ≤ 1100 350 < X ≤ 425 1500 < X ≤ 1750 950 < X ≤ 1100 1500 < X ≤ 1750
G X > 950 X > 725 X > 750 X > 600 X > 305 X > 725 X > 1100 X > 425 X > 1750 X > 1100 X > 1750

Table 3: Classification for the water ratio 2

Personal tools